Influence of environmental parameters on the accuracy of nitrogen dioxide passive diffusion tubes for ambient measurement

Kirby, C; Fox, M; Waterhouse, J; Drye, T

HERO ID

90186

Reference Type

Journal Article

Year

2001

Language

English

PMID

11253011

HERO ID 90186
In Press No
Year 2001
Title Influence of environmental parameters on the accuracy of nitrogen dioxide passive diffusion tubes for ambient measurement
Authors Kirby, C; Fox, M; Waterhouse, J; Drye, T
Journal Journal of Environmental Monitoring
Volume 3
Issue 1
Page Numbers 150-158
Abstract Two studies at three sites in the UK provided confirmation that systematic positive bias in NO2 diffusion tube measurement occurred because of changes to "within-tube" chemistry, rather than eddy diffusion at the mouth of the tube. In the first study in Cambridge, UK, sampler overestimation for 1 and 2 week exposures was compared to corresponding time-averaged monitor measurements (NO-NO2-NOx, O3) and weather variables. Noninearity between sampler and monitor NO2 measurements was interpreted in terms of spatial and temporal variations in relative and absolute availability of NO, NO2 and O3 at the site. A maximum overestimation occurred for an exposure mean NO2/NOx approximately 0.5. The separate contributions of reduced NO2 photolysis and eddy diffusion were compared in Study II using samplers of two materials, acrylic and quartz, and of different lengths (40, 55, 71 and 120 mm) at three sites: Norwich background, Cambridge intermediate, London kerbside. For compared sites, NO2 measured by acrylic samplers was significantly higher than for equivalent quartz samplers. For quartz samplers [NO2]mean was only just above the monitor at Norwich and London; sampler/monitor NO2 = 1.04 (P = 0.59) and 1.01(P = 0.76), respectively. For acrylic samplers the order of [NO2]mean was 40 mm > 120 mm > 71 mm > or = 55 mm. Excepting 40 mm samplers, this accords with a chemical bias where co-diffusing NO and 03 molecules in longer tubes have more time to react to form excess NO2. Bias in 40 mm samplers is discussed. Eddy diffusion is negligible for standard samplers because [NO2]mean was equivalent for 55 mm and 71 mm acrylic samplers and close to monitor NO2 for 71 mm quartz tubes. Both studies showed that sampler accuracy was dependent on location. Significantly, overestimation was greatest (approximately 3-4 ppb) where the NO2 annual mean was approximately 20 ppb, close to the UK and EU air quality standard of 21 ppb.
Pmid 11253011
Wosid WOS:000167055700028
Is Certified Translation No
Dupe Override No
Comments ECRIB.J. Environ. Monit. 3: 150-158.
Is Public Yes
Language Text English
Is Qa No
Relationship(s)