Development of a sampling and analytical method for the insecticide propoxur
Vasta, JF; Kvartek, EJ
| HERO ID | 66773 |
|---|---|
| In Press | No |
| Year | 1985 |
| Title | Development of a sampling and analytical method for the insecticide propoxur |
| Authors | Vasta, JF; Kvartek, EJ |
| Journal | AIHA Journal |
| Volume | 46 |
| Issue | 4 |
| Page Numbers | 230-232 |
| Abstract | A method is described for the collection and analysis of airborne propoxur (2 -(1 -Methylethoxy)phenol methylcarbamate). The sam-pling device consists of a glass absorption tube, 6.35 cm X 7.94 mm (i.d.), packed with 10% Carbowax® 400 supported on 80/100 mesh Supelcoport. The propoxur was desorbed with methanol and analyzed by liquid chromatography. Recoveries of >87% were obtained from control samples evaluated at 0.5 and 1.0 mg. The coefficient of variation for the method, including an assumed pump error of ± 5%, was 0.054. The limit of detection of the analytical method was one ng per sample. The method may be suitable for personal monitoring. Copyright 1985, American Industrial Hygiene Association |
| Doi | 10.1080/15298668591394716 |
| Wosid | WOS:A1985AFY1000011 |
| Is Certified Translation | No |
| Dupe Override | No |
| Comments | Am. Ind. Hyg. Assoc. J. 46: 230-232. Scopus URL: https://www.scopus.com/inward/record.uri?eid=2-s2.0-0021951849&doi=10.1080%2f15298668591394716&partnerID=40&md5=fa60d11b43ffb31c5f6de144a85e5c6a |
| Is Public | Yes |
| Language Text | English |
| Keyword | carbamate pesticide; insecticide; propoxur; methodology; nonhuman; priority journal |
| Is Qa | No |