Kit formulation for preparation and biological evaluation of a novel (99m)Tc-oxo complex with metronidazole xanthate for imaging tumor hypoxia

Li, Z; Lin, X; Zhang, J; Wang, X; Jin, Z; Zhang, W; Zhang, Y

HERO ID

4837177

Reference Type

Journal Article

Year

2016

Language

English

PMID

26872441

HERO ID 4837177
In Press No
Year 2016
Title Kit formulation for preparation and biological evaluation of a novel (99m)Tc-oxo complex with metronidazole xanthate for imaging tumor hypoxia
Authors Li, Z; Lin, X; Zhang, J; Wang, X; Jin, Z; Zhang, W; Zhang, Y
Journal Nuclear Medicine and Biology
Volume 43
Issue 2
Page Numbers 165-170
Abstract <strong>INTRODUCTION: </strong>Achieving an ideal (99m)Tc labeled nitroimidazole hypoxia marker is still considered to be of great interest. Metronidazole xanthate (MNXT) ligand was synthesized and radiolabeled with (99m)Tc-glucoheptonate (GH) to form the (99m)TcO-MNXT complex, for the potential use as a novel probe for imaging tumor hypoxia.<br /><br /><strong>METHODS: </strong>For labeling, (99m)TcO-MNXT was prepared by ligand-exchange reaction with (99m)Tc-GH. The radiochemical purity of the (99m)TcO-MNXT complex was measured by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). The distribution coefficient and stability of the complex was investigated. The structure of the (99m)TcO-MNXT complex was verified by preparation and characterization of the corresponding stable rhenium complex. The cellular uptake of the (99m)TcO-MNXT complex was determined in murine sarcoma S180 cell lines under hypoxic and aerobic conditions. The biodistribution and single photon emission computed tomography (SPECT) image studies of the (99m)TcO-MNXT complex were performed in mice bearing S 180 tumor.<br /><br /><strong>RESULTS: </strong>The radiochemical purity of the (99m)TcO-MNXT complex was over 90%. It had good in vitro stability and its distribution coefficient indicated that it was a hydrophilic complex. When (99m)Tc and Re complexes were coinjected in HPLC, both radioactivity (for (99m)Tc complex) and UV detectors (for Re complex) showed nearly identical HPLC profiles, suggesting their structures are similar. The tumor cell experiment and the biodistribution in mice bearing S 180 tumor showed that the (99m)TcO-MNXT complex had a good hypoxic selectivity and accumulated in the tumor with high uptake and good retention. Single photon emission computed tomography (SPECT) image studies showed that the tumor detection was observable.<br /><br /><strong>CONCLUSIONS: </strong>(99m)TcO-MNXT is prepared from a kit without the need for purification and shows high tumor uptake, tumor/blood and tumor/muscle ratios, suggesting that it would be a promising candidate for imaging tumor hypoxia.
Doi 10.1016/j.nucmedbio.2015.11.001
Pmid 26872441
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English