Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry
Fuh, CB; Lai, M; Tsai, HY; Chang, CM
HERO ID
4149695
Reference Type
Journal Article
Year
2005
Language
English
PMID
| HERO ID | 4149695 | 
|---|---|
| In Press | No | 
| Year | 2005 | 
| Title | Impurity analysis of 1,4-dioxane in nonionic surfactants and cosmetics using headspace solid-phase microextraction coupled with gas chromatography and gas chromatography-mass spectrometry | 
| Authors | Fuh, CB; Lai, M; Tsai, HY; Chang, CM | 
| Journal | Journal of Chromatography A | 
| Volume | 1071 | 
| Issue | 1-2 | 
| Page Numbers | 141-145 | 
| Abstract | 1,4-Dioxane impurity in nonionic surfactants and cosmetics were analyzed using solid-phase microextraction (SPME) coupled with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). Experimental results show that there is no significant difference using SPME-GC and SPME-GC-MS for analysis of 1,4-dioxane in three types of nonionic surfactants at the 95% confidence level. The relative standard deviation (R.S.D.) values of each analytical method were smaller than 3%. The amount of 1,4-dioxane was found to vary from 11.6 +/- 0.3 ppm to 73.5 +/- 0.5 ppm in 30% of nonionic surfactants from manufacturers in Taiwan. These methods were linear over the studied range of 3-150 ppm with correlation coefficients higher than 0.995. The recoveries of 1,4-dioxane for these nonionic surfactants following SPME were all higher than 96 +/- 1% (n = 3). The detection limits of 1,4-dioxane for these nonionic surfactants following SPME were from 0.06 ppm to 0.51 ppm. The experimentally determined level of 1,4-dioxane in cosmetics from manufacturers in Taiwan varied from 4.2 +/- 0.1 ppm to 41.1 +/- 0.6 ppm in 22% of daily used cosmetics following SPME coupled with GC and GC-MS. Conventional solvent extraction takes around 1 h for extraction and reconcentration but SPME takes only around 10 min. SPME provides better analyses of 1,4-dioxane in nonionic surfactants and cosmetics than conventional solvent extraction and head space pretreatments in term of simplicity, speed, precision, detection limit, and solvent consumption. | 
| Doi | 10.1016/j.chroma.2004.09.012 | 
| Pmid | 15865186 | 
| Wosid | WOS:000228401300021 | 
| Url | https://linkinghub.elsevier.com/retrieve/pii/S0021967304015626 | 
| Is Certified Translation | No | 
| Dupe Override | No | 
| Is Public | Yes | 
| Language Text | English |