An ultra-sensitive method for the analysis of perfluorinated alkyl acids in drinking water using a column switching high-performance liquid chromatography tandem mass spectrometry

Dasu, K; Nakayama, SF; Yoshikane, M; Mills, MA; Wright, JM; Ehrlich, S

HERO ID

3856458

Reference Type

Journal Article

Year

2017

Language

English

PMID

28336137

HERO ID 3856458
In Press No
Year 2017
Title An ultra-sensitive method for the analysis of perfluorinated alkyl acids in drinking water using a column switching high-performance liquid chromatography tandem mass spectrometry
Authors Dasu, K; Nakayama, SF; Yoshikane, M; Mills, MA; Wright, JM; Ehrlich, S
Journal Journal of Chromatography A
Volume 1494
Page Numbers 46-54
Abstract In epidemiological research, it has become increasingly important to assess subjects' exposure to different classes of chemicals in multiple environmental media. It is a common practice to aliquot limited volumes of samples into smaller quantities for specific trace level chemical analyses. A novel method was developed for the determination of 14 perfluorinated alkyl acids (PFAAs) in small volumes (10mL) of drinking water using off-line solid phase extraction (SPE) pre-treatment followed by on-line pre-concentration on a WAX column before analysis on column-switching high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). In general, large volumes (100-1000mL) have been used for the analysis of PFAAs in drinking water. The current method requires approximately 10mL of drinking water concentrated by using an SPE cartridge and eluted with methanol. A large volume injection of the extract was introduced on to a column-switching HPLC-MS/MS using a mix-mode SPE column for the trace level analysis of PFAAs in water. The recoveries for most of the analytes in the fortified laboratory blanks ranged from 73±14% to 128±5%. The lowest concentration minimum reporting levels (LCMRL) for the 14 PFAAs ranged from 0.59 to 3.4ng/L. The optimized method was applied to a pilot-scale analysis of a subset of drinking water samples from an epidemiological study. These samples were collected directly from the taps in the households of Ohio and Northern Kentucky, United States and the sources of drinking water samples are both surface water and ground water, and supplied by different water distribution facilities. Only five PFAAs, perfluoro-1-butanesulfonic acid (PFBS), perfluoro-1- -hexanesulfonic acid (PFHxS), perfluoro-1-octanesulfonic acid (PFOS), perfluoro-n-heptanoic acid (PFHpA) and perfluoro-n-octanoic acid (PFOA) are detected above the LCMRL values. The median concentrations of these five PFAAs detected in the samples was ≤4.1ng/L with PFOS at 7.6ng/L and PFOA at 10ng/L. Concentrations of perfluoro-1-decanesulfonic acid, PFDS and other perfluoroalkyl carboxylic acids were below the LCMRL values.
Doi 10.1016/j.chroma.2017.03.006
Pmid 28336137
Wosid WOS:000399512100005
Is Certified Translation No
Dupe Override No
Comments Scopus URL: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015718685&doi=10.1016%2fj.chroma.2017.03.006&partnerID=40&md5=c659a1ddda5e74a24caf8ef17d8c31c7
Is Public Yes
Language Text English
Keyword Column-switching HPLC; Drinking water; Perfluorinated alkyl acids; Solid phase extraction
Relationship(s)