A unified Perc Test-Well Permeameter methodology for absorption field investigations

Reynolds, WD

HERO ID

3559574

Reference Type

Journal Article

Year

2016

HERO ID 3559574
In Press No
Year 2016
Title A unified Perc Test-Well Permeameter methodology for absorption field investigations
Authors Reynolds, WD
Journal Geoderma
Volume 264
Page Numbers 160-170
Abstract Absorption fields are soil-based onsite installations designed to infiltrate, drain, filter or biochemically renovate water. A critical component in absorption field development is determination of the soil's ability to transmit water. Two of the most important in-situ methodologies for measuring water transmission in absorption fields are the Perc Test, which determines Perc Time (PT) in an open borehole or pit, and the Constant Head Well Permeameter (CHWP), which determines field-saturated hydraulic conductivity (K-fs) in an open borehole. Although both methods have important features, they also have deficiencies that can impair their use in absorption field investigations. Features of the Perc Test include simplicity, intuitive measurements (decline in water ponding depth, H, with time, t), and inclusion of PT criteria in most absorption field design specifications and regulatory codes. Critical deficiencies of the Perc Test include its empirical nature (absence of theoretical foundation), lack of standardization, and strong dependence of PT on borehole/pit dimensions, water ponding depth and antecedent soil properties. Features of the CHWP include a solid theoretical foundation, formal accounting for borehole dimensions, water ponding depth and soil properties, and recognition that K-fs controls long-term water acceptance rates. A critical deficiency of the CHWP is the absence of K-fs criteria from many absorption field specifications and codes. This study develops a unified Perc-CHWP analysis and application protocol that maintains the features of the Perc and CHWP tests, but circumvents the deficiencies. The unified analysis combined numerical optimization with piece-wise analytical integration of a falling-head CHWP equation; and it yielded accurate estimates of PT and K-fs using H vs. t data obtained from numerical simulations, laboratory experiments, and field-based Perc Tests. The unified Perc-CHWP methodology improves measurement of water transmission in absorption field investigations by providing: physically based PT values required by many design specifications and regulatory codes; K-fs values required for estimation of long-term water acceptance rates; and functionally linked PT-K-fs data pairs that are accurate and based on rigorous borehole infiltration theory. Crown Copyright (C) 2015 Published by Elsevier B.V. All rights reserved.
Doi 10.1016/j.geoderma.2015.10.015
Wosid WOS:000366776100017
Is Certified Translation No
Dupe Override No
Is Public Yes
Keyword Perc Test; Constant Head Well Permeameter; Field-saturated hydraulic conductivity; Absorption field; Septic tank leach field; Water transmission