Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [¹⁸F]MNI-698

Tavares, AA; Caillé, F; Barret, O; Papin, C; Lee, H; Morley, TJ; Fowles, K; Holden, D; Seibyl, JP; Alagille, D; Tamagnan, GD

HERO ID

2824029

Reference Type

Journal Article

Year

2014

Language

English

PMID

24674817

HERO ID 2824029
In Press No
Year 2014
Title Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [¹⁸F]MNI-698
Authors Tavares, AA; Caillé, F; Barret, O; Papin, C; Lee, H; Morley, TJ; Fowles, K; Holden, D; Seibyl, JP; Alagille, D; Tamagnan, GD
Journal Nuclear Medicine and Biology
Volume 41
Issue 5
Page Numbers 432-439
Abstract <strong>INTRODUCTION: </strong>A new radiotracer for imaging the serotonin 4 receptors (5-HT4) in brain, [¹⁸F]MNI-698, was recently developed by our group. Evaluation in nonhuman primates indicates the novel radiotracer holds promise as an imaging agent of 5-HT4 in brain. This paper aims to describe the whole-body biodistribution and dosimetry estimates of [¹⁸F]MNI-698.<br /><br /><strong>METHODS: </strong>Whole-body positron emission tomography (PET) images were acquired over 240 minutes after intravenous bolus injection of [¹⁸F]MNI-698 in adult rhesus monkeys. Different models were investigated for quantification of radiation absorbed and effective doses using OLINDA/EXM 1.0 software.<br /><br /><strong>RESULTS: </strong>The radiotracer main elimination route was found to be urinary and the critical organ was the urinary bladder. Modeling of the urinary bladder voiding interval had a considerable effect on the estimated effective dose. Normalization of rhesus monkeys' organs and whole-body masses to human equivalent reduced the calculated dosimetry values. The effective dose ranged between 0.017 and 0.027 mSv/MBq.<br /><br /><strong>CONCLUSION: </strong>The dosimetry estimates, obtained when normalizing organ and whole-body weights and applying the urinary bladder model, indicate that the radiation doses from [¹⁸F]MNI-698 comply with limits and guidelines recommended by key regulatory authorities that govern the translation of radiotracers to human clinical trials. The timing of urinary bladder emptying should be considered when designing future clinical protocols with [¹⁸F]MNI-698, in order to minimize the subject absorbed doses.
Doi 10.1016/j.nucmedbio.2014.02.005
Pmid 24674817
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English