Biological monitoring of occupational exposure to 1-bromopropane by means of urinalysis for 1-bromopropane and bromide ion

Kawai, T; Takeuchi, A; Miyama, Y; Sakamto, K; Zhang, ZW; Higashikawa, K; Ikeda, M

HERO ID

1733873

Reference Type

Journal Article

Year

2001

Language

English

PMID

23889306

HERO ID 1733873
In Press No
Year 2001
Title Biological monitoring of occupational exposure to 1-bromopropane by means of urinalysis for 1-bromopropane and bromide ion
Authors Kawai, T; Takeuchi, A; Miyama, Y; Sakamto, K; Zhang, ZW; Higashikawa, K; Ikeda, M
Journal Biomarkers
Volume 6
Issue 5
Page Numbers 303-312
Abstract The purposes of the present study are (1) to develop a sensitive analytical method to measure 1-bromopropane (1-BP) in urine, (2) to examine if 1-BP or bromide ion (Br) in urine is a useful biomarker of exposure to 1-BP, and (3) to identify the lowest 1-BP exposure concentration the method thus established can biomonitor. A factory survey was carried out on Friday, and 33 workers (all men) in cleaning and painting workshops participated; each worker was equipped with a diffusive sampler (carbon cloth KF-1500 as an adsorbent) to monitor 1-BP vapour for an 8-h shift, and offered a urine sample at the end of the shift for measurement of 1-BP and Br in urine. In addition, 10 non-exposed men offered urine samples as controls. The performance of the carbon cloth diffusive sampler was examined to confirm that the sampler is suitable for monitoring time-weighted average 1-BP vapour exposure. A head-space GC technique was employed for analysis of 1-BP in urine, whereas Br in urine was analysed by ECD-GC after derivatization to methyl bromide. The workers were exposed to vapours of seven other solvents (i.e. toluene, xylenes, ethylbenzene, acetone, etc.) in addition to 1-BP vapour; the 1-BP vapour concentration was 1.4 ppm as GM and 28 ppm as the maximum. Multiple regression analysis however showed that 1-BP was the only variable that influenced urinary 1-BP significantly. There was a close correlation between 1-BP in urine and 1-BP in air; the correlation coefficient (r) was >0.9 with a narrow variation range, and the regression line passed very close to the origin so that 2 ppm 1-BP exposure can be readily biomonitored. The correlation of Br in urine with 1-BP in air was also significant, but the r (about 0.7) was smaller than that for 1-BP, and the background Br level was also substantial (about 8 mg l-1). Thus, it was concluded that 1-BP in end-of-shift urine is a reliable biomarker of occupational exposure to 1-BP vapour, and that Br in urine is less reliable.
Doi 10.1080/13547500110034817
Pmid 23889306
Wosid WOS:000170235200001
Url http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=23889306
Is Certified Translation No
Dupe Override No
Comments Source: Web of Science WOS:000170235200001
Is Public Yes
Language Text English
Keyword biological monitoring; bromide ion; 1-bromopropane; diffusive sampling; occupational exposure; urinalysis